EBSILON®Professional Online Documentation
In This Topic
    Component 101: Fluid Reconverter
    In This Topic

    Component 101: Fluid Reconverter


    Specifications

    Line connections

    1

    Inlet

    2

    Outlet

    3

    Heat difference


     

    General       Displays       Example

     

    General

    This component converts a simple fluid into a universal fluid.

    The inlet stream, line 2, can be of the stream types: air, flue gas, steam, water (liquid), crude gas, oil, coal, gas, 2-phase liquid, 2-phase gaseous, salt water, user defined, universal fluid, binary mixture, thermo liquid and humid air.

    Due to the different material tables, a difference in enthalpy can occur. The respective heat quantity will be displayed on the logic line “Heat Difference”, so the user can decide on its further utilization.

     

    NCV for Fluid converter (Component 101)

    Depending on the type of conversion, it may happen that libraries are involved that do not support a calculation of the NCV. To allow an NCV to be defined at the outlet anyway, the flag FSPECNCV permits the following variants:

     

    Specification-Values

    FSPECNCV

    Method for outlet heating value specification

    Like in Parent Profile (Sub profile option only)

    Expression

    =0: Calculate from composition                       
    =1: Use specification values NCV2
    =2: Copy from inlet
    =3: Copy difference between actual and calculated (from composition) heating value

    NCV2

    Lower heating value outlet

      


     


     

     

    Component Displays

    Display Option 1

    Example

    Click here >> Component 101 Demo << to load an example.

     

    See Also