Depending upon the model, a choice must be made between 3 different output reports.
Several gas and steam turbines can be modelled in this case in the model.
The following model variants are handled:
In the case of single-shaft plants, the gas as well as the steam turbines are present on a common mechanical shaft, which gives the sum total of mechanical powers to a generator.
For making the model in EBSILON®Professional this means that the mechanical powers of the gas turbine and the mechanical power at the outlet of the gas turbine must be added and provided as the total power of the mechanical shaft at the inlet of the generator. This is done via the mixer (component 37).
For this protocol, all mechanical shafts, whose mechanical power is to be added to the mechanical inlet power of the generator, must be selected. Alternatively, the shaft or the pastille on the shaft can be selected.
Components:
Example:
Alstom Plant: KA-24 Unit: 1 R-Date: 21.12.2004 16:51:14 |
Title for the Generator, single-shaft plant |
Generator data |
Eta(n) |
Q(n) |
cos phi |
Eta |
P-wave |
P-el |
GT_POWER_Pastille |
|
|
|
|
189600.0 |
|
MECHANICAL_SHAFT_from_DT |
|
|
|
|
98941.8 |
|
Generator |
98.50 |
293200.0 |
0.85 |
98.48 |
288541.8 |
284168.5 |
Total: |
|
|
|
|
|
284168.5 |
Comments on the protocol:
If the model contains gas turbines with their own generators and these are modelled as GT-Macro (component 40, or component 57), then the mechanical power of the individual gas turbines cannot be specified, because these are not available as calculated values. Only the electrical power can be specified in this case.
For this protocol, all the GT-Macros as well as the generators of the steam turbines must be selected. In the protocol, first the GT-Macros and then the generators of the steam turbines are printed.
Components:
Example:
Alstom Plant: KA-24 Unit: 1 R-Date: 21.12.2004 16:51:14 |
Title for the Generator, GT-Macro (component 40) + DT-Generator |
Generator data |
Eta(n) |
Q(n) |
cos phi |
Eta |
P-wave |
P-el |
Gas_turbine |
|
|
|
|
|
254000.0 |
Generator |
98.00 |
283487.2 |
0.85 |
98.00 |
309450.4 |
303261.4 |
Total: |
|
|
|
|
|
557261.4 |
Alstom Plant: KA-24 Unit: 1 R-Date: 21.12.2004 16:51:14 |
Title for the Generator, GT-Macro, ABB Type (component 57) |
Generator data |
Eta(n) |
Q(n) |
cos phi |
Eta |
P-Welle |
P-el |
Gas_turbine |
|
|
0.85 |
|
|
254000.0 |
Generator |
98.00 |
283487.2 |
0.85 |
98.00 |
309450.4 |
303261.4 |
Total: |
|
|
|
|
|
557261.4 |
If the model contains gas turbines modelled from individual components, then all the mechanical and electrical values are available.
For this report, all the generators of the gas turbines as well as of the steam turbines must be selected.
Components:
Example:
Alstom Anlage: KA-24 Unit: 1 R-Datum: 21.12.2004 16:51:14 |
Title for the Generator, GT-Macro (component 40) + DT-Generator |
Generator data |
Eta(n) |
Q(n) |
cos phi |
Eta |
P-wave |
P-el |
Generator_GT |
96.00 |
6229.9 |
0.85 |
96.00 |
6229.9 |
5980.7 |
Generator_DT |
96.00 |
193.1 |
0.85 |
96.00 |
193.1 |
185.3 |
Total: |
|
|
|
|
|
6166.0 |
Even when the electrical power of the gas turbine and/or of the steam turbine is not calculated in this model, the values can still be documented.
The following structure must be used for this:
A generator is inserted, at whose outlet an electrical line is attached. The power is specified on this line via a pastille. However, the generator component must be set to "do not calculate".
In the protocol, the dummy generator is treated like a normal generator.
The components selected earlier are inserted in the sub-report in the order, in which they were selected.