Documentation of the input data as well as the output data of the gas turbine.
The gas turbine can either be modelled via the GT-Macro (component 40) or from individual components. When modeling with individual components, the combustion zone of the gas turbine as well as the generator must be specified.
The data of the gas turbine are defined as:
Depending upon the configuration the number of lines in the documentation of the data on the lines can change and hence also the appearance of the report.
The following configurations are implemented:
Component |
Name |
Line |
Fluid |
40 |
GT-Macro |
1 |
Ambient air inlet |
|
|
3 |
Fuel inlet |
|
|
4 |
Injection water/steam inlet |
|
|
2 |
flue gas outlet |
|
|
5 |
Electrical power |
Example:
Alstom Plant: KA-24 Unit: 1 R-Date: 21.12.2004 16:51:14 |
Title for the Gas Turbine (GT-Macro) |
|
M |
P |
T |
H |
Q |
Gas_turbine |
|
|
|
|
|
Material fractions of flue gas at GT-outlet: (Volume) |
|
|
|
|
N2 |
0.7596351 |
|
H2O(gas) |
0.0425766 |
O2 |
0.1589322 |
|
CO2 |
0.0297591 |
Ar |
0.0090970 |
|
|
|
Component |
Name |
Line |
Fluid |
24 |
Compressor |
1 |
Inlet |
22 |
Combustion zone |
4 |
Fuel inlet |
|
|
2 |
Flue gas outlet |
23 |
Gas turbine |
2 |
Flue gas outlet GT |
|
|
4 |
Shaft outlet (to the generator) |
11 |
Generator |
2 |
Electrical power |
Caution: The components must be specified in this order only !!!
Example:
Alstom Plant: KA-24 Unit: 1 R-Date: 21.12.2004 16:51:14 |
Title for the Gas Turbine from individual components |
|
M |
P |
T |
H |
Q |
Compressor |
|
|
|
|
|
Combustion zone |
|
|
|
|
|
Gas Turbine |
|
|
|
|
|
Generator_1 |
|
|
|
|
|
Material fractions of flue gas at GT-outlet: (Volume) |
|
|
|
|
N2 |
0.7545229 |
|
H2O(gas) |
0.0674516 |
O2 |
0.1349319 |
|
CO2 |
0.0340556 |
Ar |
0.0090380 |
|
|
|
Component |
Name |
Line |
Fluid |
57 |
GT, ABB Type |
1 |
Ambient air inlet |
|
|
3 |
Fuel inlet |
|
|
4 |
Injection water/steam inlet |
|
|
2 |
Flue gas outlet |
|
|
5 |
Electrical power |
Example:
Alstom Plant: KA-24 Unit: 1 R-Date: 21.12.2004 16:51:14 |
Title for the Gas Turbine (ABB Type) |
|
M |
P |
T |
H |
Q |
ABB___TYP |
|
|
|
|
|
Material fractions of flue gas at GT-outlet: (Volume) |
|
|
|
|
N2 |
0.3659203 |
|
CO2 |
0.1985768 |
Ar |
0.0043103 |
|
SO2 |
0.0013226 |
H2O(gas) |
0.4298699 |
|
|
|
Component |
Name |
Line |
Fluid |
76 |
ABB Reheat GT |
1 |
Ambient air inlet |
|
|
12 |
Low pressure air outlet |
|
|
13 |
High pressure air outlet |
|
|
6 |
Steam injection |
|
|
7 |
Water inlet for NOX reduction |
|
|
3 |
EV fuel inlet |
|
|
2 |
SEV fuel inlet |
|
|
5 |
High pressure air inlet |
|
|
4 |
Low pressure air inlet |
|
|
11 |
Flue gas outlet |
|
|
10 |
Shaft outlet |
11 |
Generator |
2 |
|
Caution: The components must be specified in this order only !!!
Example:
Alstom Plant: KA-24 Unit: 1 R-Date: 21.12.2004 16:51:14 |
Title for the Gas Turbine (ABB-Reheat Type) |
|
M |
P |
T |
H |
Q |
ABB_REHEAT |
|
|
|
|
|
Generator_1 |
|
|
|
|
|
Material fractions of flue gas at GT-outlet: (Volume) |
|
|
|
|
N2 |
0.3659203 |
|
CO2 |
0.1985768 |
Ar |
0.0043103 |
|
SO2 |
0.0013226 |
H2O(gas) |
0.4298699 |
|
|
|
The components selected earlier are inserted in the sub-report in the order, in which they were selected.