EBSILON®Professional Online Documentation
Data Transfer and Results Display / Create Report / The Sub-Reports / Water-Steam Cycle, Design Data
In This Topic
    Water-Steam Cycle, Design Data
    In This Topic

    Water/Steam-Path - Design data


    Documentation of the design data of the components in the Water / Steam  - circulation (without steam turbine).

     Components:

    • High Temperature Heat Exchanger (Component 51)
    • Universal Heat Exchanger (Component 55)
    • ECO / Evaporator / Super-heater, ABB Type (Component 61)
    • Duplex Heat Exchanger (Component 62)
    • Evaporator/ Drum Macro (Component 70)
    • OT - Heat Exchanger (Component 71)
    • ECO / Compressor / Super-heater, Finned Tubes (Component 73)

     

    Example:

    Alstom Plant: KA-24  Unit: 1 R-Date: 21.12.2004 16:51:14

     

    Title for the design data of the Water / Steam - Path

     

    dp(n)
    Gas
    [bar]

    dp(n)
    Steam
    [bar]

    K*A(n)

    [kW/K]

    Alpha
    Gas
    [W/m**2K]

    Alpha
    Steam
    [W/m**2K]

    Exp
    Gas
    [-]

    Exp
    Steam
    [-]

    TQ

    [°C]

    ABB___Typ_4

    0.003

    0.60

    1141.8

    50.00

    500.00

    0.610

    0.784

    136.0

    Evaporator

    0.003

    0.15

    697.3

    50.00

     

    0.610

     

    212.2

    integr__ECO_EVA_SUP

    0.003

    0.30

    882.6

    50.00

    500.00

    0.610

    0.000

    280.0

    Duplex_heat_exchanger

    0.003
    0.003

    0.24
    0.20

    87.9
    5.6

    50.00
    50.00

    500.00
    500.00

    0.610
    0.610

    0.784
    0.784

    322.9
    322.9

    integr__ECO_EVA_SUP_2

    0.003

    1.30

    357.4

    50.00

    500.00

    0.610

    0.000

    545.3

    ABB___type

    0.003

    1.55

    212.4

    50.00

    500.00

    0.610

    0.784

    605.7

    integr__ECO_EVA_SUP_3

    0.003

    0.30

    62.5

    50.00

    500.00

    0.610

    0.000

    642.6

     

     Remarks on the report:

    • dp Gas is the pressure loss in the gas path (nominal)
    • dp Dampf is the pressure loss in the steam path (nominal)
    • K*A(n) corresponds to K*A (nominal)
    • Alpha G means Alpha Gas, heat-transfer coefficient of gas
    • Alpha D means Alpha Steam, heat-transfer coefficient of steam
    • Exp G is the mass flow exponent for gas
    • Exp D is the mass flow exponent for steam
    • TQ is the average flue gas temperature (nominal)


    Generate sub-report 

    • Select all heat-exchanger components in the water/steam path of the model.
      The sequence of selection must be in the direction of flow.
    • Call the dialog box "Modifying Sub-Reports".
    • Select the sub-report "Water/Steam - Path, Design Data" and import it in the list of the sub-report.
    • Enter an extra title, if needed.
    • Select the sub-report for the design data of the water/steam path and thereafter click the button "Modify" or double-click the sub-report for the design data of the water/steam path.
      The dialog box "Edit Sub-Report" opens.
    • A click on the button "Insert (Select)" the component selected earlier in the cycle is added in the list of the components of the sub-report.
    • Close the dialog box for the list of the components through the button "Close".
    • Close the dialog box for modifying the sub-protocol through the button "Close".

     

    The components selected earlier are added in the sub-report in the order in which they were selected.

    In case several water/steam paths have to be documented, it can be done in different ways by splitting or merging the lines. As a result, separate sub-reports of this type must be generated for each.