Line connections |
||
1 |
Inlet |
|
2 |
Outlet |
|
General User Input Values Physics Used Displays Example
The control valve defines pressure P1 in front of the component according to the following rules:
P1 = P2 for P2 >= P1MIN
P1 = P1MIN for P2 < P1MIN
Along with these rules, the following relations are also applicable for the pressure calculation:
H1 = H2 and M1 = M2
As these components can also be used as a valve, the design of these components can be toggled between flap and valve.
Similar components:
Component 68 (valve):
This component functions like component 59 with the difference that the holding pressure P1MIN can be changed by means of a control connection.
P1MIN |
Minimum pressure |
All cases |
||
if P2 >= P1MIN, then { P1 = P2 } else { P1 = P1MIN } H2 = H1 T2 = f (P2, H2) M2 = M1 Q2 = Q1 |
Display Option 1 |
Display Option 2 |
Click here >> Component 59 Demo << to load an example.