    Component 4: Splitter (Mass Defined)
    In This Topic

    Component 4: Splitter (Mass defined)


    Specifications

    Line connections

    1

    Fluid inlet

    2

    Fluid outlet

    3

    Branch

     

    General       User Input Values       Physics Used       Displays       Example

     

    General

    In component 4, the split ratio of the inlet flow must be defined outside of this component. This is best done by placing a component 33 (start value) on line 3.

    Alternative splitters are

           - Component 17       Split definition by characteristic

           - Component 18       Split definition in fraction of the main flow


    User Input Values

     

    No specifications are necessary!


    Physics Used

    Equations

    All cases

     

         P2 = P1                                           

         P3 = P1                                           

         T2 = T1

         T3 = T1

         H2 = H1                                           

         H3 = H1                                            

         M2 = M1 - M3                                  

         NCV2 = NCV1 (NCV=[lower]calorific value)

         NCV3 = NCV1

     

    Component Displays

    Display Option 1

    Display Option 2

    Example

    Click here >> Component 4 Demo << to load an example.