Line connections |
||
1 |
Main flow inlet |
|
2 |
Main flow outlet |
|
3 |
Auxiliary flow inlet |
General User Input Values Physics Used Displays Example
With component 37 the main flow 1 and the auxiliary flow 3 are mixed together. The assumption is that there is no throttling of the pressure of the main flow within the component. This means that the pressure of the auxiliary flow is the same as the pressure of the main flow. It is taken from the main flow. So just the enthalpy and the flow rate have to be defined in the auxiliary flow.
Component 3 is a similar component, but it includes throttling i.e. the pressure of the auxiliary flow must be higher than the pressure of the main flow.
FSPECX allows defining on which pins a composition is to be specified. However, this flag can only be used if the material equations are integrated into the equation system.
(Model option -->Simulation --> Iteration, Level of integration of material equations).
FSPECX |
Flag for Handling - Material-equation Like in Parent Profile (Sub Profile option only) Expression =0: Any given |
All cases |
||
|
M2= M1 + M3 P2 = P1 H2*M2 = H1*M1 + H3*M3 T2 = f(P2,H2) if line 2 delivers wet steam, then X2 = f(P2,H2)
Q2 = Q1 + Q3 NCV2 = (NCV1*M1 + NCV3*M3) / M2
|
|
Display Option 1 |
Display Option 2 |
Click here >> Component 37 Demo << to load an example.