Documentation of the input as well as the output data of fuel pre-heating. The values are taken from the heat-exchanger at the input and the output lines of the fuel respectively .
Components:
Example:
Alstom Plant: KA-24 Unit: 1 R-Date: 21.12.2004 16:51:14 |
Title for Fuel Pre-heating |
|
M |
P |
T |
H |
Q |
NCV |
ABB___Type_3 |
10.620 |
42.80 |
31.50 |
69.3 |
735.7 |
50000 |
In the first line, the basic quantities at the primary inlet, and in the second line, the basic quantities at the primary outlet are specified. In addition, the value of the "Net Calorific Value" is also given.
Only the heat exchanger need to be clicked for the sub-report. The heat-exchanger must be connected to the primary inlet or the outlet of a fuel line respectively. The primary line of a heat-exchanger is defined in EBSILON®Professional from connection 1 (primary inlet) to connection 2 (primary outlet).
If the fuel pre-heating is not implemented in the model by a heat-exchanger, then one comparison measurement point each must be set on the fuel line before and after the heating. These comparison measurement points can then be specified for the fuel pre-heating. Thereby, you must be careful of the sequence while selecting: