    Example of a Report-Structure


     

    A sample structure of the documentation with the sequence of the main groups and the sub-reports.

    1. Settings

    1.1. Sub-report "EBSILON Professional General"

    1.2. Sub-report "EBSILON Professional Settings"

    1.3. Sub-report "EBSILON Professional Calculation"

    1.4. Sub-report "EBSILON Professional Warning Messages"

    1.5. Page Feed

     

    2. Plant Data

    2.1. Sub-report "Plant Data"

     

    3. Generator

    3.1. Sub-report "Generator"

     

    4. Auxiliary Load

    4.1. Sub-report "Auxiliary Load"

     

    5. Gas Turbine

    5.1. Sub-report "Gas Turbine"

    5.2. Sub-report "Pastille with Material Data" for fuel data before pre-heater

    5.3. Sub-report "Fuel pre-heating"

    5.4. Sub-report "Pastille on air pipe" for Air OTCs and possibly for ambient air

    5.5. Sub-report "Pastille with Material Data" for flue gas data at the GT-outlet

     

    6. Additional firing

    6.1. Sub-report "Additional Firing" with fuel data before additional firing and with flue gas data after additional firing

    6.2. Page Feed

     

    7. Flue gas path

    Arrangement of the components in the direction of flow

    7.1. Sub-report "Flue gas path - Process data"

    7.2. Sub-report "Flue gas path - Design data" (heat flow)

    7.3. Page Feed

     

    8. Water / Steam Path

    Arrangement of the components in the direction of flow

    8.1. Sub-report "Feed water tank"

    8.2. Sub-report "Water / Steam Path - Process data"

    8.3. Sub-report "Water / Steam Path – Design data"

    8.4. Page Feed

     

    9. Steam turbine

    9.1. Sub-report "Steam turbine – Process data"

    9.2. Sub-report "Steam turbine – Design data"

     

    10. Condenser & Preheater

    10.1. Sub-report "Condenser & Preheater"

     


    Explanation of the contents of the main group: Flue gas path:


    Following sequence and content:

    • Basically, the components must be given in the direction of flow.

     

    Flue gas system

    • Starting from inlet of heat-recovery boiler or the outlet of additional firing till the outlet of heat-recovery boiler

     


    Explanation of the contents of the main group: Water / Steam – Path:


    Following sequence and content:

    • Basically, the components must be given in the direction of flow, starting from the system with the highest pressure till the system with the lowest pressure.
      Branching must be handled depending upon the case.

     

    High Pressure System

    • Starting from the outlet of the feed water tank (if available), or starting from the inlet of the heat-recovery boiler (if no feed water tank is available),
    • till the inlet of steam turbine HP-steam

     

    Average Pressure System

    • Starting from the outlet of feed water tank (if available and if separate feed water pump for AP), or
      starting from outlet of feed water pumps – AP-feed water extraction (if no separate feed water pump for AP),
    • till the inlet of steam turbine AP-steam

     

    Low Pressure System

    • Starting from outlet of feed water tank (if available and if separate feed water pump for LP or AP/LP), or
      starting from outlet of feed water pumps – LP- or AP/LP-feed water extraction (if no separate feed water pump for LP or AP/LP),
    • till the inlet of steam turbine LP-steam

     

    Reheater-System (Reheat Steam)

    • Starting from outlet of steam turbine Reheat-outlet,
    • till inlet of steam turbine Reheat-inlet